Konaktelcit
Engineering Tool

3D PANEL FENCE WEIGHT PER M²

V-pressed 3D panels weigh 3–8% more than flat 2D panels because of the bends. Enter the vertical and horizontal wire diameters, mesh openings and bend depth + pitch — kg/m², panel mass and total tonnage come out instantly.

Inputs

mm

Typical for 3D panels: 5.0–6.0 mm

mm

Usually equal to or 0.5 mm thinner than vertical

mm

Distance between two horizontal wires (mm)

mm

Distance between two vertical wires (mm)

V-Press
mm

V-press bend height (mm). Typical 25–35 mm.

mm

Distance between two bend peaks (mm). Typical 150–250 mm.

×

Number of V-presses on a single vertical wire — typically 2–5 by panel height.

mm

Single-panel horizontal length (mm). Typical 2500 mm.

mm

Single-panel vertical height (mm). Typical 1530–2030 mm.

×

Provide a panel count to see total tonnage

Formula

k = 2 · √((p/2)² + h²) / p   (curve factor)
m/m² = k · ρ_v + ρ_h   (kg/m²)

p: bend pitch (mm). h: bend depth (mm). k: factor by which a single bend stretches the vertical wire — typically 1.03–1.08. ρ_v: vertical-wire kg/m² contribution as in flat 2D, ρ_h: horizontal-wire contribution. Only verticals get k; horizontals stay flat. Larger depth or smaller pitch raises k.

Result

No calculation yet

Enter wire diameters, mesh openings, bend depth and pitch — then press Calculate to see results here.

Quick reference — 3D panel curve factors

Curve factors for common V-press combinations and the resulting mass per m² for a 5 mm vertical / 5 mm horizontal panel with 200 × 50 mm mesh. Production tolerance ±3%.

Bend (h × p)Factor kkg/m² (5×5, 200×50)
25 × 250 mm1.0203.52
25 × 200 mm1.0313.54
30 × 200 mm1.0443.58
30 × 150 mm1.0773.66
35 × 200 mm1.0603.62
40 × 200 mm1.0773.66

Production tolerance

When the bends are pressed, vertical wire length deviates by ±1.5 mm and bend depth by ±1 mm. Apply ±3% tolerance to per-m² mass. For large orders, the factory weighbridge ticket rules.

Surface coating

Standard 3D panel: electro-galvanised + polyester powder coating (RAL 6005 green, 7016 anthracite, 9005 black). Coating adds ~0.15–0.25 kg/m². For corrosive sites use heavy galvanised (80 μm) + powder topcoat as a duplex system.