3D PANEL FENCE WEIGHT PER M²
V-pressed 3D panels weigh 3–8% more than flat 2D panels because of the bends. Enter the vertical and horizontal wire diameters, mesh openings and bend depth + pitch; kg/m², panel mass and total tonnage come out instantly.
Inputs
Formula
k = 2 · √((p/2)² + h²) / p (curve factor) m/m² = k · ρ_v + ρ_h (kg/m²)
p: bend pitch (mm). h: bend depth (mm). k: factor by which a single bend stretches the vertical wire, typically 1.03–1.08. ρ_v: vertical-wire kg/m² contribution as in flat 2D, ρ_h: horizontal-wire contribution. Only verticals get k; horizontals stay flat. Larger depth or smaller pitch raises k.
Result
No calculation yet
Enter wire diameters, mesh openings, bend depth and pitch, then press Calculate to see results here.
Quick reference: 3D panel curve factors
Curve factors for common V-press combinations and the resulting mass per m² for a 5 mm vertical / 5 mm horizontal panel with 200 × 50 mm mesh. Production tolerance ±3%.
| Bend (h × p) | Factor k | kg/m² (5×5, 200×50) |
|---|---|---|
| 25 × 250 mm | 1.020 | 3.52 |
| 25 × 200 mm | 1.031 | 3.54 |
| 30 × 200 mm | 1.044 | 3.58 |
| 30 × 150 mm | 1.077 | 3.66 |
| 35 × 200 mm | 1.060 | 3.62 |
| 40 × 200 mm | 1.077 | 3.66 |
Production tolerance
When the bends are pressed, vertical wire length deviates by ±1.5 mm and bend depth by ±1 mm. Apply ±3% tolerance to per-m² mass. For large orders, the factory weighbridge ticket rules.
Surface coating
Standard 3D panel: electro-galvanised + polyester powder coating (RAL 6005 green, 7016 anthracite, 9005 black). Coating adds ~0.15–0.25 kg/m². For corrosive sites use heavy galvanised (80 μm) + powder topcoat as a duplex system.